24 research outputs found

    Focal adhesion size controls tension-dependent recruitment of α-smooth muscle actin to stress fibers

    Get PDF
    Expression of α-smooth muscle actin (α-SMA) renders fibroblasts highly contractile and hallmarks myofibroblast differentiation. We identify α-SMA as a mechanosensitive protein that is recruited to stress fibers under high tension. Generation of this threshold tension requires the anchoring of stress fibers at sites of 8–30-μm-long “supermature” focal adhesions (suFAs), which exert a stress approximately fourfold higher (∼12 nN/μm2) on micropatterned deformable substrates than 2–6-μm-long classical FAs. Inhibition of suFA formation by growing myofibroblasts on substrates with a compliance of ≤11 kPa and on rigid micropatterns of 6-μm-long classical FA islets confines α-SMA to the cytosol. Reincorporation of α-SMA into stress fibers is established by stretching 6-μm-long classical FAs to 8.1-μm-long suFA islets on extendable membranes; the same stretch producing 5.4-μm-long classical FAs from initially 4-μm-long islets is without effect. We propose that the different molecular composition and higher phosphorylation of FAs on supermature islets, compared with FAs on classical islets, accounts for higher stress resistance

    Experimenting Liver Fibrosis Diagnostic by Two Photon Excitation Microscopy and Bag-of-Features Image Classification

    Get PDF
    The accurate staging of liver fibrosis is of paramount importance to determine the state of disease progression, therapy responses, and to optimize disease treatment strategies. Non-linear optical microscopy techniques such as two-photon excitation fluorescence (TPEF) and second harmonic generation (SHG) can image the endogenous signals of tissue structures and can be used for fibrosis assessment on non-stained tissue samples. While image analysis of collagen in SHG images was consistently addressed until now, cellular and tissue information included in TPEF images, such as inflammatory and hepatic cell damage, equally important as collagen deposition imaged by SHG, remain poorly exploited to date. We address this situation by experimenting liver fibrosis quantification and scoring using a combined approach based on TPEF liver surface imaging on a Thioacetamide-induced rat model and a gradient based Bag-of-Features (BoF) image classification strategy. We report the assessed performance results and discuss the influence of specific BoF parameters to the performance of the fibrosis scoring framework.Romania. Executive Agency for Higher Education, Research, Development and Innovation Funding (research grant PN-II-PT-PCCA-2011-3.2-1162)Rectors' Conference of the Swiss Universities (SCIEX NMS-CH research fellowship nr. 12.135)Singapore. Agency for Science, Technology and Research (R-185-000-182-592)Singapore. Biomedical Research CouncilInstitute of Bioengineering and Nanotechnology (Singapore)Singapore-MIT Alliance (Computational and Systems Biology Flagship Project funding (C-382-641-001-091))Singapore-MIT Alliance for Research and Technology (SMART BioSyM and Mechanobiology Institute of Singapore (R-714-001-003-271)

    A Protein Inventory of Human Ribosome Biogenesis Reveals an Essential Function of Exportin 5 in 60S Subunit Export

    Get PDF
    A systematic search for human ribosome biogenesis factors shows conservation of many aspects of eukaryotic ribosome synthesis with the well-studied process in yeast and identifies an export route of 60S subunits that is specific for higher eukaryotes

    An Easy Path for Correlative Electron and Super-Resolution Light Microscopy

    No full text
    A number of new Correlative Light and Electron Microscopy approaches have been developed over the past years, offering the opportunity to combine the specificity and bio-compatibility of light microscopy with the high resolution achieved in electron microscopy. More recently, these approaches have taken one step further and also super-resolution light microscopy was combined with transmission or scanning electron microscopy. This combination usually requires moving the specimen between different imaging systems, an expensive set-up and relatively complicated imaging workflows. Here we present a way to overcome these difficulties by exploiting a commercially available wide-field fluorescence microscope integrated in the specimen chamber of a Scanning Electron Microscope (SEM) to perform correlative LM/EM studies. Super-resolution light microscopy was achieved by using a recently developed algorithm - the Super-Resolution Radial Fluctuations (SRRF) - to improve the resolution of diffraction limited fluorescent images. With this combination of hardware/software it is possible to obtain correlative super-resolution light and scanning electron microscopy images in an easy and fast way. The imaging workflow is described and demonstrated on fluorescently labelled amyloid fibrils, fibrillar protein aggregates linked to the onset of multiple neurodegenerative diseases, revealing information about their polymorphism.ISSN:2045-232

    Nuclear motility in glioma cells reveals a cell-line dependent role of various cytoskeletal components.

    No full text
    Nuclear migration is a general term for the movement of the nucleus towards a specific site in the cell. These movements are involved in a number of fundamental biological processes, such as fertilization, cell division, and embryonic development. Despite of its importance, the mechanism of nuclear migration is still poorly understood in mammalian cells. In order to shed light on the mechanical processes underlying nuclear movements, we adapted a micro-patterning based assay. C6 rat and U87 human glioma cells seeded on fibronectin patterns--thereby forced into a bipolar morphology--displayed oscillatory movements of the nucleus or the whole cell, respectively. We found that both the actomyosin system and microtubules are involved in the nuclear/cellular movements of both cell lines, but their contributions are cell-/migration-type specific. Dynein activity was necessary for nuclear migration of C6 cells but active myosin-II was dispensable. On the other hand, coupled nuclear and cellular movements of U87 cells were driven by actomyosin contraction. We explain these cell-line dependent effects by the intrinsic differences in the overall mechanical tension due to the various cytoskeletal elements inside the cell. Our observations showed that the movements of the nucleus and the centrosome are strongly correlated and display large variation, indicating a tight but flexible coupling between them. The data also indicate that the forces responsible for nuclear movements are not acting directly via the centrosome. Based on our observations, we propose a new model for nuclear oscillations in C6 cells in which dynein and microtubule dynamics are the main drivers of nuclear movements. This mechanism is similar to the meiotic nuclear oscillations of Schizosaccharomyces pombe and may be evolutionary conserved

    Exon skipping of cathepsin B : mitochondrial targeting of a lysosomal peptidase provokes cell death

    No full text
    The alternatively spliced messenger RNA of the human cysteine peptidase cathepsin B missing exons 2 and 3 encodes a truncated form of the enzyme lacking the signal peptide and part of the inhibitory propeptide. This deletion results in a new N-terminal leader sequence characteristic of proteins predestined for transport into mitochondria. We determined enzyme targeting to intracellular organelles by transfecting HeLa cells with constructs containing segments of variable length of the N terminus of truncated cathepsin B fused to green fluorescent protein. Co-localization of the constructs with mitochondria and the endoplasmic reticulum was probed with specific markers. None of the chimeric products were found in the endoplasmic reticulum, showing that truncated cathepsin B is misrouted from its regular biosynthetic pathway and forced to enter the mitochondria instead of lysosomes as its final destination. The first 20 amino acids of the new N terminus were necessary and sufficient for mitochondrial targeting, but only cells expressing the complete truncated cathepsin B sequence died by nuclear fragmentation. This new and unexpected behavior draws attention to an additional extralysosomal role for a cysteine peptidase with several recognized important pathophysiological functions. Mitochondrial targeting of cathepsin B may have significant consequences on cell life in pathological or physiological situations characterized by excessive transcription of the cathepsin B message lacking exons 2 and 3, as observed for instance in osteoarthritic cartilage

    Tocopherol Cyclase (VTE1) Localization and Vitamin E Accumulation in Chloroplast Plastoglobule Lipoprotein Particles

    Get PDF
    Chloroplasts contain lipoprotein particles termed plastoglobules. Plastoglobules are generally believed to have little function beyond lipid storage. Here we report on the identification of plastoglobule proteins using mass spectrometry methods in Arabidopsis thaliana. We demonstrate specific plastoglobule association of members of the plastid lipid-associated proteins/fibrillin family as well as known metabolic enzymes, including the tocopherol cyclase (VTE1), a key enzyme of tocopherol (vitamin E) synthesis. Moreover, comparative analysis of chloroplast membrane fractions shows that plastoglobules are a site of vitamin E accumulation in chloroplasts. Thus, in addition to their lipid storage function, we propose that plastoglobules are metabolically active, taking part in tocopherol synthesis and likely other pathways

    Automated suppression of sample-related artifacts in Fluorescence Correlation Spectroscopy

    Get PDF
    Fluorescence Correlation Spectroscopy (FCS) in cells often suffers from artifacts caused by bright aggregates or vesicles, depletion of fluorophores or bleaching of a fluorescent background. The common practice of manually discarding distorted curves is time consuming and subjective. Here we demonstrate the feasibility of automated FCS data analysis with efficient rejection of corrupted parts of the signal. As test systems we use a solution of fluorescent molecules, contaminated with bright fluorescent beads, as well as cells expressing a fluorescent protein (ICA512-EGFP), which partitions into bright secretory granules. This approach improves the accuracy of FCS measurements in biological samples, extends its applicability to especially challenging systems and greatly simplifies and accelerates the data analysis. (C) 2010 Optical Society of Americ
    corecore